Ster-L-Ray High Output Ultraviolet Germicidal Lamps
STER-L-RAY High Output (HO) germicidal lamps are similar in size
and shape to conventional germicidal lamps but are capable of operating
at higher input power and current. Atlantic Ultraviolet's Surelite
ballasts have been extensively tested with STER-L-RAY High Output
(HO) lamps and are strongly recommended to achieve the best performance
and longest lamp life. STER-L-RAY High Output germicidal lamps
are widely used in forced air duct systems and water disinfections
applications. HO ozone producing lamps are often found in odor control
and photochemical applications.
Lamp
Description |
Length (mm) Base Face to Base Face |
Arc
Length
(mm) |
Lamps
Watts
1 |
Approx.
Lamp Current
mA |
UV Output at
254 nm |
Rated Effective Hours |
Watts 2 |
uW/cm2 3 |
GPH436T5L/HO/4PSE |
436 |
360 |
48 |
800 |
13 |
120 |
9,000 |
GPH436T5/VH/HO/4PSE |
436 |
360 |
48 |
800 |
13 |
120 |
9,000 |
GHO36T5/L/4PSE |
843 |
755 |
87 |
800 |
28 |
260 |
9,000 |
GHO36T5/VH/4PSE |
843 |
755 |
87 |
800 |
28 |
260 |
9,000 |
GPH846T5/L/HO/4PSE |
846 |
767 |
90 |
800 |
29 |
265 |
9,000 |
GPH846T5/VH/HO/4PSE |
846 |
767 |
90 |
800 |
29 |
265 |
9,000 |
GPH893T5/L/HO/4PSE |
893 |
815 |
95 |
800 |
30 |
270 |
9,000 |
GPH893T5/VH/HO/4PSE |
893 |
815 |
95 |
800 |
30 |
270 |
9,000 |
GHO64T5/L/4PSE |
1554 |
1421 |
155 |
800 |
45 |
380 |
9,000 |
GHO64T5VH/4PSE |
1554 |
1421 |
155 |
800 |
45 |
380 |
9,000 |
Those considering the use of HO lamps in a new application
are advised to consult one of Atlantic Ultraviolet's Application
Engineers for specific recommendations.
1 Wattage is lamp watts only and does not include ballast
loss.
2 Ultraviolet output at 254 nanometers at 100 hours and 80oF (approximate).
3 Microwatts per square centimeter at one meter from lamp.
4 Approximate ozone output in grams per hour under favorable conditions.
Figures apply only to ozone producing types. Please note that ozone
output is subject to considerable variation due to conditions under
which the lamp is used; under many conditions, the ozone output
may be only a fraction of the specified figure.
---
Please note that ozone output is subject to considerable variation
due to conditions under which the lamp is used; under many conditions,
the ozone output may be only a fraction of the specified figure.
|